Abstract
This paper analyzes the working principle of VIENNA rectifier and establishes
the transformation model of rectifier in three different mathematical coordinate
systems. First is to obtain the control structure of the converter, which
is a double closed loop control structure (the voltage is the outer loop
control and the current is the inner loop control). By using a feed forward
control strategy to solve the problem of phase-to-phase coupling. By adding
the voltage equalization loop and using the midpoint balance algorithm
to solve the problem of the voltage imbalance caused by the rectifier under
load. Finally, uses MATLAB to build the model, simulates and verifies the
established model system.